Thông số kỹ thuật chính

ParameterValueNote
Product featuresSpecification NameSpecifications and Parameters
Reference inputInput Frequency0.5MHz~30MHz40MHz~75MHz80MHz~110MHz
Input Channels1-
Input Power3dBm~15dBmOperates normally from 0dBm to 17dBm
Input Signal Impedance50 ohm-
Input Signal WaveformContinuous Sine Wave / Continuous Square Wave-
Measurement InputInput Frequency0.5MHz~30MHz40MHz~75MHz80MHz~110MHz
Input Channels4-
Input Power3dBm~15dBmOperates normally from 0dBm to 17dBm
Input Signal Impedance50 ohm-
Input Signal WaveformContinuous Sine Wave / Continuous Square Wave-

ParameterValueNote
Measurement OutputStability (10MHz) (25℃±1℃) (Sampling Time 1s)≤2.0E-14@1s≤4.0E-15@10s≤8.0E-16@100s≤1.6E-16@1000s
InterfaceCommunication InterfaceRJ45 (Communication Network Port)

DB9 (Debug Serial Port)

ParameterValueNote
Signal inputSMA-K-
Mechanical19-inch chassis420mm*44mm*390mm
Ambient TemperatureOperating Temperature-20℃→+50℃
Storage temperature-55℃→+85℃-
Power SupplySupply VoltageAC220V±10%
Power Consumption≤50W-
Interface Type3-pin IEC male connector-
OtherMeasurement SoftwareProvides supporting measurement software

Tính năng

  • Measurement Frequency Range: 0.5MHz~30MHz, 40MHz~75MHz, 80MHz~110MHz;
  • Frequency Stability: ≤2E-14 (Typical: 1.4E-14)
  • Multi-channel: 4 channels (4 DUT channels, 1 reference channel);
  • Among multiple DUT signals, among reference signals, same frequency is not required;
  • Minimum Sampling Interval: 1ms~1000s (Configurable);
  • Equipped with host computer, measurement results are displayed and stored in real time;
  • Stability Test Supports Upper Computer Offline Function;
  • Each measurement channel independently controlled, switching between channels does not affect each other;
  • Each channel can be custom-configured with a channel name, facilitating user management and data analysis;

Related Resources