Menu
Home
Products
Resources
Blog Contact
Request Quote

Overview

The BRIDZA STW-NT series network time servers provide high-performance NTP and PTP (IEEE 1588v2) synchronization for enterprise networks, data centers, and telecommunications infrastructure. With throughput exceeding 140,000 NTP responses per second and timing accuracy within 25ns to UTC, these servers are the backbone of precision timing for modern networks.

Supported Models

Model NTP Response Rate PTP Support Oscillator
------- ------------------ ------------- ------------
STW-NT100 100,000/s Yes OCXO
STW-NT200 140,000/s Yes Rubidium (optional)

Front Panel Layout

 ┌────────────────────────────────────────────────────────────────┐
 │ BRIDZA STW-NT200 NETWORK TIME SERVER │
 │ │
 │ ┌──────┐ ┌──────┐ ┌──────┐ ┌──────┐ ┌──────┐ ┌──────┐ │
 │ │ PWR │ │ ETH1 │ │ ETH2 │ │ GNSS │ │ PTP │ │ ALM │ │
 │ │ ● │ │ ● │ │ ● │ │ ● │ │ ● │ │ ○ │ │
 │ └──────┘ └──────┘ └──────┘ └──────┘ └──────┘ └──────┘ │
 │ │
 │ NETWORK PORTS GNSS ANTENNA TIME OUTPUTS │
 │ ┌──────┐ ┌──────┐ ┌──────┐ ┌──────┐ ┌────┐ │
 │ │ ETH1 │ │ ETH2 │ │ ANT │ │ 1PPS │ │10M │ │
 │ │RJ45 │ │RJ45 │ │ ● │ │ OUT │ │Hz │ │
 │ └──────┘ └──────┘ └──○───┘ └──○───┘ └──○─┘ │
 │ │
 │ ┌──────────────────────────────────────────────────────────┐ │
 │ │ ALARM 1PPS IN DC INPUT CONSOLE │ │
 │ │ ┌────┐ ┌────┐ ┌────┐ ┌────┐ │ │
 │ │ │RELAY│ │BNC │ │ ○- │ │USB │ │ │
 │ │ └────┘ └────┘ └────┘ └────┘ │ │
 │ └──────────────────────────────────────────────────────────┘ │
 │ │
 │ MODEL: STW-NT200 S/N: __________ REV: 3.0 │
 └────────────────────────────────────────────────────────────────┘

Interface Definitions

1. Network Ports

Parameter Specification
----------- ---------------
Connectors 2× RJ45, 10/100/1000BASE-T
Standards IEEE 802.3, 802.3u, 802.3ab
Auto-negotiation Yes
MAC Address Labeled on unit

Pin Assignment (RJ45):

 ┌───────────────┐
 │ 8 7 6 5 4 3 2 1 │
 │ │ │ │ │ │ │ │ │ │
 │ ┴─┴─┴─┴─┴─┴─┴─┴ │
 │ │
 Pin 1: TX+ │
 Pin 2: TX- │
 Pin 3: RX+ │
 Pin 6: RX- │
 Pins 4,5,7,8: NC │
 └───────────────────┘

2. NTP Protocol

Parameter Specification
----------- ---------------
Version NTP v4 (RFC 5905)
Mode Server, Client, Symmetric Passive
Throughput >140,000 responses/sec
Accuracy ≤25μs (local network)
Authentication MD5, SHA-1, AES
Access Control ACL-based

3. PTP (IEEE 1588v2)

Parameter Specification
----------- ---------------
Profile Default (General), Power (PoweDev)
Domain 0-255 (configurable)
Mode Master, Slave, Transparent Clock
Delay Mechanism P2P, E2E
Accuracy ≤25ns to Grandmaster
VLAN 802.1Q supported

4. GNSS Antenna Input

Parameter Specification
----------- ---------------
Connector SMA female
DC Power 5V @ 100mA
Supported GPS, BeiDou, GLONASS
Timing Accuracy ≤25ns RMS

5. 1PPS Input

Parameter Specification
----------- ---------------
Connector BNC female
Level TTL (3.3V/5V)
Impedance 50Ω
Pulse Width 1μs to 10ms
Accuracy ≤±100ns to UTC

6. 1PPS/10MHz Output

Parameter 1PPS Output 10MHz Output
----------- ------------- --------------
Connector BNC female SMA female
Level TTL/LVPECL 13dBm
Impedance 50Ω 50Ω
Jitter ≤500ps -

7. Alarm Output

Parameter Specification
----------- ---------------
Connector Terminal block (3-pin)
Type Form C relay
Rating 0.5A @ 30VDC
Functions GNSS fault, Holdover, Power failure

Pin Assignment:

 ┌─────────────────┐
 │ NC COM NO │
 │ │ │ │ │
 │ └──┬─┘ │ │
 │ │ │ │
 └──────┴──────┴───┘
 
 NC: Normally Closed
 COM: Common
 NO: Normally Open

Configuration Methods

Web Interface

  • URL: http://
  • Default: 192.168.1.100
  • Username: admin
  • Password: admin

CLI (Console/RS232)

Parameter Specification
----------- ---------------
Connector USB (virtual COM) or RS232 (DB9)
Baud Rate 115200
Data Bits 8
Parity None
Stop Bits 1

CLI Commands:

# Network Configuration
network set eth0 static 192.168.1.100/24 192.168.1.1
network set dns 8.8.8.8

# NTP Configuration
ntp server add 0.pool.ntp.org
ntp server list
ntp enable

# PTP Configuration
ptp mode master
ptp domain 0
ptp enable

# GNSS Configuration
gnss mode gps+beidou
gnss ant delay 30

# Status
show status
show gnss
show ntp
show ptp

SNMP

OID Description
----- -------------
1.3.6.1.4.1.x.1.1 System uptime
1.3.6.1.4.1.x.2.1 NTP status
1.3.6.1.4.1.x.2.2 GNSS status
1.3.6.1.4.1.x.2.3 Holdover duration

Power Supply

Parameter Specification
----------- ---------------
Voltage +12VDC or 100-240VAC (with adapter)
Current 1.5A @ 12VDC
Power ≤20W
Connector 5.5×2.1mm DC jack

Mechanical Dimensions

 482mm (19" rack width)
 ┌─────────────────────────────────────┐
 │ │ 44mm (1U)
 │ STW-NT200 │
 │ NETWORK TIME SERVER │
 │ │
 │ [ETH1][ETH2] [ANT] [1PPS][10M] │
 │ │
 └─────────────────────────────────────┘
 └── 300mm ──┘

Typical Configuration

# Initial Setup
connect 192.168.1.100
login admin admin

# Configure for Primary Time Source
ntp master stratum 1
gnss enable
ntp enable

# Configure PTP Grandmaster
ptp enable
ptp mode master
ptp powerprofile disable

# Add Backup NTP Servers
ntp server add 1.pool.ntp.org
ntp server add 2.pool.ntp.org

# Save Configuration
config save

Troubleshooting

Symptom Cause Solution
--------- ------- ----------
ETH LED off Cable disconnected Check Ethernet cable
- Wrong speed/duplex Set auto-negotiation
NTP timeout Firewall blocking Open UDP 123
- Stratum too high Check server configuration
PTP not working VLAN mismatch Verify VLAN settings
- Delay mechanism Verify P2P/E2E setting
GNSS LED off Antenna issue Check antenna and cable
Holdover active GNSS signal lost Check antenna position

Download Resources


Document Version: 1.0

Last Updated: 2026-05-24

BRIDZA Technologies

Need Technical Support?

Contact our engineering team for detailed specifications and custom configurations.

Request a Quote